01
Water ingress behind cladding
Water rarely enters where the stain appears. Failed sealant joints, open laps, and cracked cladding create entry points two floors above the leak inside.
How it shows up. Interior staining, efflorescence on exterior masonry, saturated insulation, mold at window jambs.
02
Air barrier breach
Warm interior air escaping through gaps in the air barrier hits cold sheathing and condenses. The result is mold, rot, and structural degradation inside the wall cavity.
How it shows up. Damp sheathing behind intact cladding, musty odour, drafts at outlets, frost on interior corners in winter.
03
Thermal bridging
Uninsulated structural elements conduct heat through the wall assembly, creating cold spots, condensation, and excessive heating loads on individual suites.
How it shows up. Cold spots on thermal imaging, condensation streaks at slab edges, uneven heating bills between identical suites.
04
Cladding deterioration
Fibre cement delamination, concrete spalling, EIFS cracking, sealant oxidation. Caught early, recladding stays a planned maintenance item. Left too long, it becomes a full remediation.
How it shows up. Hairline cracks at panel joints, spalled concrete, chalking or oxidised sealant, lifting at fibre cement laps.
05
Balcony & deck interfaces
Where horizontal meets vertical is where water concentrates. Flashing failures, membrane terminations and threshold details are the most frequent failure point in BC strata envelope systems.
How it shows up. Staining under balcony slabs, lifting membrane at thresholds, ponding water, rust streaks at railing anchors.